Aranet T/RH probe (ammonia resistant)

$290.00

Aranet T/RH probe is resistant to ammonia and offers extremely accurate measurements of temperature and relative humidity.
The probe is completely suitable for tough settings thanks to its IP67 class.
The sensor is frequently utilised in hen houses.

Categories: ,

Description

  1. Designed for chemically harsh environment
  2. Measures temperature and relative humidity
  3. IP67 casing
  4. Up to 3 km / 1.9 mi range
  5. Flexibility of installation
Aranet T/RH probe (ammonia resistant)
Aranet T/RH sensor with Radiation Shield

TDSPT409 (EU)

TDSPT4U9 (NA)

TDSPT4R9 (RU)

Sensor performance
Temperature
Relative
Range
-40 °C to 85 °C (-40 °F to 185 °F)
0-100%
Resolution
0.1 °C (0.1 °F)
0.1%
Accuracy1
±0.3 °C (±0.5 °F)
± 2%
Hysteresis
N/A
± 1%
Long-term drift
0.03 °C/year (0.05 °F/year)
0.5%/year
Radio parameters
Line of sight range
3 km (1.9 mi)
Supported ISM bands

EU868, NA915

Transmitter power

14 dBm

Data transmission interval3

1, 2, 5 or 10 minutes

Data protection

XXTEA encryption

Compatible base stations

Aranet PRO

Power 1 AA battery
Type
Alkaline7
Lithium8
Operating
-20 °C to 55 °C
-40 °C to 60 °C
temperature
(-4 °F to 131 °F)
-40 °F to 140 °F)
TX interval
Battery lifetime at 20 °C (68 °F)9
1 Minute
1.3 years
1.7 years
2 minutes
2.3 years
3.0 years
5 minutes
4.8 years
6.8 years
10 minutes
8.2 years
10+ years
General
Ingress Protection code
IP67
Maximum operating

-40 °C to 60 °C

temperature range

(-40 °F to 140 °F)

Dimensions

Ø 35 x 120 mm
(Ø 1.4 x 4.7 in)

Weight6

100 g (3.5 oz)

Enclosure material
ASA, plastics
Included in the box
1 AA alkaline battery, polyester string
Compliance
CE
Conformité Européenne
IC

Innovation, Science and Economic
Development Canada

FCC

Federal Communications Commission
(USA)

1 99% of the sensors measure within these typical limits in equilibrium state at time of sale. For evaluation of the total measurement error
hysteresis and long-term drift has to be taken into account.

2 Temperature accuracy is provided for a range 0 … +60 °C.

3 Humidity accuracy is provided at temperature +23 °C for a range 0 … 80% RH.

4 Relative humidity drift value is provided at laboratory conditions: +23 °C and 30% RH to 70% RH. At temperatures higher than +50 °C over
a longer period of time, an increased long-term drift can occur.

5 Due to regulatory requirements 1 minute data transmission interval is not available in Russia.

6 Weight with alkaline AA Fujitsu LR6G07 Premium battery.

7 AA Fujitsu LR6G07 Premium battery used for tests and calculations.

8 AA Energizer L91 Ultimate Lithium battery used for tests and calculations.

9 Battery lifetime data has been obtained by mathematical extrapolation and is provided for descriptive purposes only and is not intended to
make or imply any guarantee or warranty