Aranet T/RH probe

$215.00

Aranet T/RH probe sensors have an IP class of 67 and are hermetically sealed, which guarantees remarkable longevity. Energy-efficient wireless sensors can last more than ten (10) years without a battery change. In addition to being easily removed and calibrated, the probe can also be modified or extended, which may be necessary for some unique projects or requirements.

 

Categories: ,

Description

  1. Measures temperature and relative humidity
  2. IP67 casing
  3. Up to 3 km / 1.9 mi range
  4. Flexibility of installation
Aranet T/RH probe
Measures the temperature and relative humidity of the environment

TDSPT309 (EU)

TDSPT3U9 (NA)

TDSPT3R9 (RU)

Sensor performance
Temperature
Relative Humidity
Range
-40 °C to 85 °C (-40 °F to 185 °F)
0-100%
Resolution
0.1 °C (0.1 °F)
0.1%
Accuracy1
±0.3 °C (±0.5 °F)
± 2%
Hysteresis
N/A
± 1%
Long-term drift
0.03 °C/year (0.05 °F/year)
0.5%/year
Radio parameters
Line of sight range
3 km (1.9 mi)
Supported ISM bands

EU868, NA915

Transmitter power

14 dBm

Data transmission interval3

1, 2, 5 or 10 minutes

Data protection

XXTEA encryption

Compatible base stations

Aranet PRO

Power 1 AA battery
Type
Alkaline4
Lithium5
Operating
-20 °C to 55 °C
-40 °C to 60 °C
temperature
(-4 °F to 131 °F)
(-40 °F to 140 °F)
TX interval
Battery lifetime at 20 °C (68 °F)6
1 Minute
1.3 years
1.7 years
2 minutes
2.3 years
3.0 years
5 minutes
4.8 years
6.8 years
10 minutes
8.2 years
10+ years
General
Ingress Protection code
IP67
Maximum operating

-40 °C to 60 °C

temperature range

(-40 °F to 140 °F)

Dimensions

Ø 35 x 120 mm
(Ø 1.4 x 4.7 in)

Weight3

100 g (3.5 oz)

Enclosure material
ASA plastic
Included in the box
1 AA alkaline battery, polyester string
Compliance
CE
Conformité Européenne
IC

Innovation, Science and Economic
Development Canada

FCC

Federal Communications Commission
(USA)

Aranet qualifies its T/RH sensor to work properly within ambient clean air. Qualification for use in harsh environment is the duty of the user of the sensor. Exposure to volatile organic compounds, acids or bases, etching substances such as H2O2, NH3, shall be avoided.

_________________

1. 95% of the sensors measure within these typical limits in equilibrium state at time of sale. For evaluation of the total measurement error
hysteresis and long-term drift has to be taken into account.

2. Due to regulatory requirements 1 minute data transmission interval is not available in Russia.

3. Weight with alkaline AA Fujitsu LR6G07 Premium battery.

4. AA Fujitsu LR6G07 Premium battery used for tests and calculations.

5. AA Energizer L91 Ultimate Lithium battery used for tests and calculations.

6. Battery lifetime data has been obtained by mathematical extrapolation and is provided for descriptive purposes only and is not intended to
make or imply any guarantee or warranty.

Additional information

Weight 1 lbs

Documentation

Reviews

There are no reviews yet.

Be the first to review “Aranet T/RH probe”

Your email address will not be published. Required fields are marked *