T/RH sensor IP42

$95.00

Aranet T/RH sensor measures temperature and relative humidity.

Way to its high sturdiness, it could be positioned exterior or in a completely humid indoor environment, IP-42 (forty two).

Categories: ,

Description

All Aranet sensors are terrific with their excellence in strength-saving ensuring the functioning of the battery for up to 10 years.
  1. Measures temperature and relative humidity
  2. Up to 3 km / 1.9 mi range
  3. IP42 class
  4. Up to 10 years of battery life
  5. 5 Flexibility of installation
Aranet T/RH sensor
Measures the temperature and relative humidity of the environment

TDSPT001 (EU)

TDSPT0U1 (NA)

TDSPT0R1 (RU)

Sensor performance
Temperature
Relative
Range
-40 °C to 60 °C (-40 °F to 140 °F)
0-100%
Resolution
0.1 °C (0.1 °F)
1%
Accuracy1
±0.3 °C (±0.5 °F)
± 2%
Hysteresis
N/A
± 1%
Long-term drift
0.03 °C/year (0.05 °F/year)
0.5%/year
Time constant τ (63%)2
10 minutes
TBD
Radio parameters
Line of sight range
3 km (1.9 mi)
Supported ISM bands

EU868, NA915

Transmitter power

14 dBm

Data transmission interval3

1, 2, 5 or 10 minutes

Data protection

XXTEA encryption

Compatible base stations

Aranet PRO

Power 2 AA battery
Type
Alkaline5
Lithium6
Operating
-20 °C to 55 °C
-40 °C to 60 °C
temperature
(-4 °F to 131 °F)
(-40 °F to 140 °F)
TX interval
Battery lifetime at 20 °C (68 °F)7
1 Minute
2.4 years
2.6 years
2 minutes
4.3 years
4.9 years
5 minutes
8.3 years
10 years
10 minutes
10 years
10+ years
General
Ingress Protection code
IP42
Maximum operating

-40 °C to 60 °C

temperature range

(-40 °F to 140 °F)

Dimensions

111 x 44 x 25 mm
(4.5 x 1.7 x 1.0 in)

Weight4

65 g (2.3 oz)

Enclosure material
ASA plastic
Included in the box
2 AAA alkaline batteries, polyester string
Compliance
CE
Conformité Européenne
IC

Innovation, Science and Economic
Development Canada

FCC

Federal Communications Commission
(USA)

Aranet qualifies its T/RH sensor to work properly within ambient clean air. Qualification for use in harsh environment is the duty of the user of the sensor. Exposure to volatile organic compounds, acids or bases, etching substances such as H2O2, NH3, shall be avoided.

1. 95 % of the sensors measure within these typical limits in equilibrium state at time of sale. For evaluation of the total measurement error
hysteresis and long-term drift has to be taken into account.

2. Time constant is determined at 1 m/s airflow.

3. Due to regulatory requirements 1 minute data transmission interval is not available in Russia.

4. Weight with alkaline AAA Fujitsu LR03G07 Premium batteries.

5. AAA Fujitsu LR03G07 Premium batteries used for tests and calculations.

6. AAA Energizer L92 Ultimate Lithium batteries used for tests and calculations.

7. Battery lifetime data has been obtained by mathematical extrapolation and is provided for descriptive purposes only and is not intended to
make or imply any guarantee or warranty

Additional information

Weight 1 lbs

Documentation

Reviews

There are no reviews yet.

Be the first to review “T/RH sensor IP42”

Your email address will not be published. Required fields are marked *